Support > Hardware Help & Info

MP3100, 3200, 3300, 3400

Note: these pages are excerpted from the User's Manual P/N MP3000-UM-151.

DIP Switch Settings and Functions

DIP Switch 1
Bit No 8 7 6 5 4 3 2 1
Meaning Do not use STOP BIT Parity Character length RS control Handshake I/F Mode
ON -- 2-bit Even Parity bit used 8-bit Always ON Xon/Xoff RS-232C
OFF Always 1-bit Odd None 7-bit On during transmission Hardware Parallel
Bit number 8
Bit No 8
Meaning Orientation
On Upright (60°)
Off Horizontal
Bit number 3-2
Bit No 3 2
On ESC commands input to buffer PLOTTER OFF ignored
Off Usually Usually

When Using HP-GL Commands

SW2
Bit No. 10 9 8 7 6 5 4 3 2 1
Meaning Pencil Pen sorting Step size Command Paper size Baud rate
On Activated Activated 0.025 mm see 
see
see
Off Deactivated Deactivated 0.1 mm
Bits 7-6
7 6 Command Type
-- On MP Dig plot
On -- FP personal
-- -- HP-GL
Bits 5-4
5 4 Paper size
-- -- ISO  A3
On -- ANSI B
-- On ISO  A4
On On ANSI A
Bits 3-2-1
9600 -- -- On
4800 -- On --
2400 -- On On
1200 On -- --
600 On -- On
300 On On --

Notes:
"--" in any of the tables above means "OFF".
Upper side is ON and lower side is OFF

The MP3100, MP3200, MP3300 do not have switches 2-9 and 2-10