DIP Switch Settings and Functions

4.0 Command Modes

Your digitizer comes equipped with functions that support Graphtec commands and other command sets. Thse command functions can be selected by setting the menu area. The five available command modes are above -- click on these links to jump to sections 4.2,. 4.3, 4.4, and 4.5.

The Command Modes

Click function key A of the menu area to select the command mode and access that mode's functions. For instructions on setting the menu area, see section 3.7, "Setting the Menu Area's Functions."

KW3320 controls

Function

Settings

Command mode Graphtec commands bu_sqr2.jpg (5405 bytes) MM commands
bu_sqr2.jpg (5405 bytes) DT commands bu_sqr4.jpg (5389 bytes) Serial mouse mode
Wintab Driver mode (beeper enabled) bu_sqr6.jpg (5396 bytes) Wintab Driver mode (Beeper disabled)

Your digitizer initially comes with the command mode set to Graphtec commands. For more information, see section 4.6 "Factory Default Settings."

Check:

Settings cannot be separately registered for each command mode. When the END key is pressed after changing any settings at the menu area, the previously registered settings will be updated.

4.1 Settings in the Graphtec Command Mode

KW3320 figure 4.1

Functions

Settings

Command mode

Graphtec commands

Baud rate

19200 bps

bu_sqr2.jpg (5405 bytes) 9600 bps

bu_sqr2.jpg (5405 bytes) 4800 bps

bu_sqr4.jpg (5389 bytes) 2400 bps

1200 bps

bu_sqr6.jpg (5396 bytes) . . . . . . .

DATA length & No. of stop bits

8 bits, 2 bits

bu_sqr2.jpg (5405 bytes) 8 bits, 1 bit

bu_sqr2.jpg (5405 bytes) 7 bits, 2 bits

bu_sqr4.jpg (5389 bytes) 7 bits, 1 bit

. . . . . . .

bu_sqr6.jpg (5396 bytes) . . . . . . .

Parity mode & Terminator

NONE, CR/LF

bu_sqr2.jpg (5405 bytes) NONE, LF

bu_sqr2.jpg (5405 bytes) ODD, CR/LF

bu_sqr4.jpg (5389 bytes) ODD, LF

EVEN, CR/LF

bu_sqr6.jpg (5396 bytes) EVEN, LF

Output format

ASCII

bu_sqr2.jpg (5405 bytes) BINARY-1

bu_sqr2.jpg (5405 bytes) BINARY-2

bu_sqr4.jpg (5389 bytes) . . . . . . .

. . . . . . .

bu_sqr6.jpg (5396 bytes) . . . . . . .

Step resolution

0.1 mm

bu_sqr2.jpg (5405 bytes) 0.025 mm

bu_sqr2.jpg (5405 bytes) 0.005 in.

bu_sqr4.jpg (5389 bytes) 0.001 in.

. . . . . . .

bu_sqr6.jpg (5396 bytes) . . . . . . .

Data transmission mode

Remote

bu_sqr2.jpg (5405 bytes) Point

bu_sqr2.jpg (5405 bytes) Stream

bu_sqr4.jpg (5389 bytes) Switch Stream

. . . . . . .

bu_sqr6.jpg (5396 bytes) . . . . . . .

Data transfer rate (points/s)

MAX

bu_sqr2.jpg (5405 bytes) 100

bu_sqr2.jpg (5405 bytes) 30

bu_sqr4.jpg (5389 bytes) 10

  . . . . . . .

bu_sqr6.jpg (5396 bytes) . . . . . . .

Beeper & E-SW (Function extension switch) status

Beeper Enabled, E-SW Valid

bu_sqr2.jpg (5405 bytes) Beeper Disabled, E-SW Valid

bu_sqr2.jpg (5405 bytes) Beeper Enabled, E-SW Invalid

bu_sqr4.jpg (5389 bytes) Beeper Disabled, E-SW Invalid

  . . . . . . .

bu_sqr6.jpg (5396 bytes) . . . . . . .

Note:

In the "Setting" column, an underlined setting indicates the default setting.

Any setting indicated as ". . . . . . ." specifies the default setting, so that value may be specified instead of the underlined setting.