Support > Hardware

KW3300, 4300, 4600

MM Command Set

bul_tri_red.gif (844 bytes) 4.0 DIP Switch Settings and Functions bul_tri_red.gif (844 bytes) 7.1 DT Commands bul_tri_red.gif (844 bytes) 7.2 HDG Commands
bul_tri_red.gif (844 bytes) 7.3 Bit Pad II Commands bul_tri_red.gif (844 bytes) 7.4 MM Series Commands bul_tri_red.gif (844 bytes) 7.5 Serial Mouse Mode

7.4 MM Command Set

7.4.1 DIP Switch Functions
(a)
Settings of DIP Switch 1
The bits of this switch select the default settings of the resolution, output format, data transmission mode, and data transfer rate.
Function SW1
1 2 3 4 5 6 7 8
Output format ASCII ON          
Binary OFF
Resolution 500 lpi   ON
0.1 mm OFF
Data transmission mode Remote mode   OFF OFF
Point mode ON
Switch stream mode ON OFF
Stream mode ON
Data transfer rate max/32   ON ON
max/8 OFF
max/2 OFF ON
max OFF
Fixed to OFF   OFF OFF
(b)
Settings of DIP Switch 2
The bits of this switch select the default settings of the RS-232C interface conditions and terminator character.
Function DIP Switch 2
1 2 3 4 5 6 7 8
Terminator CR/LF ON        
CR OFF
Data length 7 bits   ON
8 bits OFF
Parity bit NONE   OFF --
ODD ON OFF
EVEN ON
Stop bit 1 bit   ON
2 bits OFF
Baud rate 19200 bits/s   ON ON ON
9600      " OFF
4800      " OFF ON
2400      " OFF
1200      " OFF ON ON
600      " OFF
300      " OFF ON
150      " OFF
(c)
Settings of DIP Switch 3
The bits of this switch select the detault settings of the command mode (MM emulation), coordinate pointer, and beeper mode.
Function DIP Switch 3
1 2 3 4 5 6 7 8
Command mode OFF ON ON        
Stylus pen   OFF
4-button cursor ON
Beeper Enabled   ON
  Disabled   OFF
Fixed to OFF   OFF OFF OFF