Support > Hardware

KW3300, 4300, 4600

DT Command Set

Note: these pages are excerpted from the User's Manual, part number KW4300-UM-151.

bul_tri_red.gif (844 bytes) 4.0 DIP Switch Settings and Functions bul_tri_red.gif (844 bytes) 7.1 DT Commands bul_tri_red.gif (844 bytes) 7.2 HDG Commands
bul_tri_red.gif (844 bytes) 7.3 Bit Pad II Commands bul_tri_red.gif (844 bytes) 7.4 MM Series Commands bul_tri_red.gif (844 bytes) 7.5 Serial Mouse Mode

7.1 DIP Switch Functions

7.1.1 The DIP Switch Functions

The bits of this switch select the default settings of the resolution, output format, and data transmission mode.

Function DIP Switch 1
1 2 3 4 5 6 7 8
Output format BCD (F + F2) ON ON ON      
BCD (F) OFF
BCD (F2) OFF ON
ASCII BINARY OFF
BINARY OFF ON ON
Resolution 0.005 inch   ON
0.1 mm OFF
Data transmission mode Point   OFF OFF OFF
Stream ON
Switch stream ON OFF
Idle ON
Increment ON   OFF
Fixed to OFF   OFF
(b)
Settings of DIP Switch 2
The bits of this switch select the default settings of the RS-232C interface conditions and terminator character
Function DIP Switch 2
1 2 3 4 5 6 7 8
Logical Terminator Append ON        
Omit OFF
Data length 7 bits   ON
8 bits OFF
Parity bit NONE   OFF ---
ODD ON OFF
EVEN ON
Stop bit 1 bit   ON
2 bits OFF
Baud rate 19200 bits/s   ON ON ON
9600 " OFF
4800  " OFF ON
2400  " OFF
1200  " OFF ON ON
600  " OFF
300  " OFF ON
150  " OFF
(c)
Settings of DIP Switch 3
The bits of this switch select the default settings of the command mode (DT emulation) coordinate pointer, beeper mode, etc.
  DIP Switch 3
1 2 3 4 5 6 7 8
Command mode OFF OFF ON        
Stylus pen   OFF
4-button cursor ON
Beeper Enabled   ON
Disabled OFF
Fixed to OFF   OFF OFF OFF