Support > Hardware Help & Info

KD3220, 3320, 4320, 4620, 3820

DIP Switch Settings and Functions

4.0 DIP Switch Settings and Functions

This chapter describes the functions of the Graphtec command set. For a description of the functions of other command sets, see Chapter 7, "DESCRIPTION OF OTHER COMMAND SETS."

4.1 The DIP Switch Functions

The DIP switches determine the default settings of the digitizer (the settings that will take effect when the digitizer is initially turned on). Before connecting your digitizer to a computer, be sure to check the settings of the DIP switches.

(1) Functions of DIP Switch 1

The bits of this switch select the default settings of the resolution, output format, and data transmission (coordinate-reading) mode.

Function SW1
1 2 3 4 5 6 7 8
Command mode Graphtec OFF OFF  
Output format ASCII   ON OFF  
BINARY-1 OFF ON
BINARY-2 OFF OFF
Resolution 0.1mm   OFF OFF  
0.025mm OFF ON
0.005 in. ON OFF
0.001 in. ON ON
Data transmission mode Remote mode   OFF OFF
Point mode
ON
Stream mode ON OFF
Switch stream mode ON

Description of DIP Switch SW1 functions

Command mode:
Set bits 1 and 2 to OFF to select the Graphtec command mode
Data output format:
Set bits 3 and 4 to select the format of the data to be sent to the computer (coordinate data and flag data) to one of three output formats: ASCII, BINARY-1, or BINARY-2.
Resolution:
Set bits 5 and 6 to select the unit resolution of coordinate positions to one of four values: 0.1 mm, 0.025 mm, 0.005 inch, or 0.001 inch.
Data transmission mode:
Set bits 7 and 8 to select one of four data transmission modes: Remote, Point, Stream, or Switch Stream.
(2) Functions of DIP Switch 2

The bits of this switch select the default settings of the RS-232C interface conditions and terminator character.

Table 4-2 Settings of DIP switch SW2
  DIP SW 2
1 2 3 4 5 6 7 8
Fixed to OFF OFF  
Terminator LF   ON  
CR+LF OFF
Data length 7 bits   ON  
8 bits OFF
Parity check None   OFF  
Odd   ON ON  
Even   ON ON  
Stop bit 1 bit   ON  
2 bits OFF
Baud rate (bits/s) 19200   ON ON
9600  OFF
4800 OFF ON
2400 OFF

Description of DIP Switch SW2 functions

Terminator:
This terminator indicates the end of a block of ASCII format data. Set bit 2 of DIP switch SW2 to select either LF (line feed) or CR+LF (Carriage return + Line Feed).
Data length:
Set bit 3 to set the number of DATA bits per character to 7 or 8 bits.
Parity check mode:
When parity check is enabled, the number of even or odd bits being transferred is verified during bit transmission. Set bits 4 and 5 to select no parity check (none), even parity check (Even), or odd parity check (Odd).
Number of stop bits:
A stop bit indicates the end of a character during data transmission. Set bits 6 to select one or two stop bits per character.
Baud rate:
Set bits 7 and 8 to select the data transfer rate as the number of bits to be transmitted per second. The baud rate can be set within a range to 2400 to 19,200 bits/second.
(2) Factory Presets

Your digitizer's DIP switches come preset to the default settings shown in Figure 4-1 below:


SW1

BLACK in the lower row indicates OFF
  1 2 3 4 5 6 7 8
ON                
OFF                

SW2

  1 2 3 4 5 6 7 8
ON                
OFF                

SW3

  1 2 3 4 5 6 7 8
ON                
OFF                

Table 4-3 Description of the factory presets

Type Function Factory preset
Interface conditions Baud rate 9,600 bps
Parity check None
No. of Stop bits 2
Data length 7 bits
Digitizer functions Command mode Graphtec
Output format ASCII
Terminator CR+LF
Resolution 0.1 mm
Data transmission mode Remote