Support > Hardware

KD3200, 3300, 3800, 4300, 4600

DIP Switch Settings and Functions

bul_tri_red.gif (844 bytes) 5.0 DIP Switch Settings and Functions bul_tri_red.gif (844 bytes) 11.1 DT4100 Commands
bul_tri_red.gif (844 bytes) 11.2 HDG Command bul_tri_red.gif (844 bytes) 11.3 Bit Pad Two Commands bul_tri_red.gif (844 bytes) 11.4 MM Series Commands

11.4 MM Series Commands

Note:
the MM commands differ from the Summagraphics MM series with respect to the following points:

11.4.1 DIP Switch Setting Method
(a)
DIP Switch SW1
DIP Switch SW1 is used to set the output format and coordinate reading mode
Function SW1
1 2 3 4 5 6 7 8
Output format ASCII ON            
Binary OFF
Terminator CR LF   ON
CR OFF
Fixed     OFF
Beeper Enabled   ON
Disabled OFF
Remote mode   OFF OFF
Point mode ON ON
Switch stream mode OFF ON
Stream mode ON OFF
Data transfer rate max/32   ON ON
max/8 ON OFF
max/2 OFF ON
max OFF OFF
(b)
DIP Switch SW2
DIP Switch SW2 is used to set the resolution and data transfer conditions.
Function SW2
1 2 3 4 5 6 7 8
Resolution 500 lines/inch ON        
0.1 mm OFF
Data length 7 bits   ON
8 bits OFF
Parity bit NONE   OFF  *
ODD ON OFF
EVEN ON ON
Stop bit 1 bit   ON
2 bits OFF
Baud rate 9600 bits/s   ON ON ON
4800 " ON OFF ON
2400 " ON OFF OFF
1200 " OFF ON ON
600 " OFF ON OFF
300 " OFF OFF ON
150 " OFF OFF OFF
*
Settable to either on or off
(c)
DIP Switch SW3
DIP Switch SW3 is used to set the out-of-area data output and other-manufacturer compatible command functions.
Function SW3
1 2 3 4 5 6 7 8
Command mode MM Series OFF OFF OFF ON OFF OFF OFF OFF