Support > Hardware

KD3200, 3300, 3800, 4300, 4600

DIP Switch Settings and Functions

bul_tri_red.gif (844 bytes) 5.0 DIP Switch Settings and Functions bul_tri_red.gif (844 bytes) 11.1 DT4100 Commands
bul_tri_red.gif (844 bytes) 11.2 HDG Command bul_tri_red.gif (844 bytes) 11.3 Bit Pad Two Commands bul_tri_red.gif (844 bytes) 11.4 MM Series Commands

11.2 HDG Command

Note:
The HDG Series command specifications differ from the Hitachi Seiko HDG series with respect to the following points:

11.2.1 DIP Switch Setting Method
(a)
DIP Switch SW1
DIP Switch SW1 is used to set the resolution and coordinate reading mode
Function SW2
1 2 3 4 5 6 7 8
Resolution 0.025 mm OFF OFF OFF    
0.05 mm OFF OFF ON
0.1 mm OFF ON OFF
0.254 mm OFF ON ON
1000 lines/inch ON OFF OFF
400 lines/inch ON OFF ON
200 lines/inch ON ON OFF
100 lines/inch ON ON ON
Remote mode   OFF OFF
Switch stream mode   OFF ON
Stream mode   ON OFF
Point mode   ON ON
Data transfer rate 2 data/s   OFF OFF OFF
4 " OFF OFF ON
10    " OFF ON OFF
20    " OFF ON ON
45    " ON OFF OFF
55    " ON OFF ON
ON ON OFF
ON ON ON
(b)
DIP Switch SW2
DIP Switch SW2 is used to set the terminator and data transfer conditions.
Function SW2
1 2 3 4 5 6 7 8
Terminator CRLF ON        
CR OFF
Data length 7 bits   ON
8 bits OFF
Parity bit NONE   OFF    *1
ODD ON OFF
EVEN ON ON
Stop bit 1 bit   ON
2 bits OFF
Baud rate 9600 bits/s   ON ON ON
4800 " ON OFF ON
2400 " ON OFF OFF
1200 " OFF ON ON
600 " OFF ON OFF
300 " OFF OFF ON
150 " OFF OFF OFF
*1
Can be set to either ON or OFF
(c)
DIP Switch SW3
DIP Switch SW3 is used to set the out-of-area data output and other-manufacturer command compatible functions

This switch is used to set command compatibility to digitizers of other manufacturers.

Function SW3
1 2 3 4 5 6 7 8
Command mode HDG series OFF OFF OFF OFF ON ON    
Leading zero suppression Enabled             ON  
Disabled             OFF  
Beeper Enabled               ON
Disabled               OFF