DIP Switch Settings and Functions

bul_tri_red.gif (844 bytes) 5.0 DIP Switch Settings and Functions bul_tri_red.gif (844 bytes) 11.1 DT4100 Commands
bul_tri_red.gif (844 bytes) 11.2 HDG Command bul_tri_red.gif (844 bytes) 11.3 Bit Pad Two Commands bul_tri_red.gif (844 bytes) 11.4 MM Series Commands

11.1 DT4100 Commands

11.1.1 DIP Switch Setting Method
(a)
DIP Switch SW1
DIP Switch SW1 is used to set the output format and coordinate reading mode
Function SW1
1 2 3 4 5 6 7 8
Output format ASCII binary OFF OFF OFF        
Binary ON ON ON
BCD (F) ON OFF OFF
BCD (F + F2) ON OFF ON
BCD (F2) ON ON OFF
CURSOR/ pen status 1 (cursor)   ON
0 (stylus) OFF
Logical terminator Appended   ON
Not appended OFF
Point mode   OFF OFF OFF
Stream mode OFF OFF ON
Switch stream mode ON ON ON
Idle mode OFF ON ON
Increment mode ON OFF OFF
(b)
DIP Switch SW2
DIP Switch SW2 is used to set the resolution and data transfer conditions
Function SW2
1 2 3 4 5 6 7 8
Resolution 0.005" ON        
0.1 mm OFF
Data length 7 bits   ON
8 bits OFF
Parity bit NONE   OFF  *1
ODD ON OFF
EVEN ON ON
Stop bit 1 bit   ON
2 bits OFF
Baud rate 9600 bits/s   ON ON ON
4800 " ON OFF ON
2400 " ON OFF OFF
1200 " OFF ON ON
600 " OFF ON OFF
300 " OFF OFF ON
150 " OFF OFF OFF
*1
Settable to either on or off
(c)
DIP Switch SW3
DIP Switch SW3 is used to set the out-of-area data output and other-manufacturer compatible command functions.
Function SW3
1 2 3 4 5 6 7 8
Command mode DT4100 OFF OFF OFF OFF OFF OFF    
O-AREA output No output   OFF OFF
Output 1 time OFF ON
Continuous output ON ON