KD3200, 3300, 3800, 4300, 4600

DIP Switch Settings and Functions

bul_tri_red.gif (844 bytes) 5.0 DIP Switch Settings and Functions bul_tri_red.gif (844 bytes) 11.1 DT4100 Commands
bul_tri_red.gif (844 bytes) 11.2 HDG Command bul_tri_red.gif (844 bytes) 11.3 Bit Pad Two Commands bul_tri_red.gif (844 bytes) 11.4 MM Series Commands

11.3 Bit Pad Two Commands

11.3.1 DIP Switch Setting Method
(a)
DIP Switch SW1
DIP Switch SW1 is used to set the output format and coordinate reading mode
Function SW1
1 2 3 4 5 6 7 8
Output format ASCII ON            
Binary OFF
Terminator CR LF   ON
CR OFF
Coordinate system Relative   ON
Absolute OFF
PROX (out of area) flag Output   ON
Not output OFF
Remote mode   *   OFF OFF OFF OFF
Point mode * ON ON OFF OFF
Switch stream mode * 150  data/s   OFF ON ON ON
65 " ON OFF
40 " OFF ON
20 " OFF OFF
Stream mode * 150  "   ON OFF ON ON
65 " ON OFF
40 " OFF ON
20 " OFF OFF
*
Verify that positions 7 and 8 of switch SW3 have been set to OFF. If these are not set to OFF, the Increment mode will be enabled.
(b)
DIP Switch SW2
DIP Switch SW2 is used to set the resolution and data transfer conditions
Function SW2
1 2 3 4 5 6 7 8
Resolution 0.005" ON        
0.1 mm OFF
Data length 7 bits   ON
8 bits OFF
Parity bit NONE   OFF  *1
ODD ON OFF
EVEN ON ON
Stop bit 1 bit   ON
2 bits OFF
Baud rate 9600 bits/s   ON ON ON
4800 " ON OFF ON
2400 " ON OFF OFF
1200 " OFF ON ON
600 " OFF ON OFF
300 " OFF OFF ON
150 " OFF OFF OFF
*1
Settable to either on or off
(c)
DIP Switch SW3
DIP Switch SW3 is used to set the out-of-area data output and other-manufacturer compatible command functions.
Function SW3
1 2 3 4 5 6 7 8
Command mode BIT PAD TWO OFF OFF OFF OFF ON OFF    
Increment mode Disabled   OFF OFF
Step 1 OFF ON
Step 5 ON OFF
Step 10 ON ON